Power Supply DP100¶
ALIENTEK DC Power Supply DP100

Ref. I found hidden gem on AliExpress. This power supply amazed me.
Specifications¶
| Modle | DP100 |
|---|---|
| Input | USB Type-C |
| Output | 4.0mm Banana jack |
| Communication | USB - A |
| Screen | 0.96’ 160 x 80 IPS LCD |
| Dimensions | 100.4mm x 62.2mm x 17.2mm |
| Input Protection | REP / UVP |
| Output Protection | OVP / OCP / OPP / OTP / REP |
| Output Mode | CC / CV |
| Ripple Voltage | ≤2mVrms, 10mVp-p |
| Ripple Current | ≤1mArms, 3mAp-p |
| Setting Resolution(V/C) | 10mV / 1mA |
| Input Voltage | DC 5V ~ 32V |
| Input Current | 100mA ~ 5A |
| Input Voltage | DC 00.00 ~ 30.00V |
| Input Current | DC 0.000 ~ 5.000A |
| Output Power | 100W Max |
| Full Load Efficiency | ≤97%(30V, 3.33A) |
User manual¶
Unofficial Manual_JP
Manuals.Plus_JP

① Read back voltage of input, which is power supply voltage, the unit is V.
② Output voltage setting, 00.00~30.00V, resolution 0.01V, unit V.
③ Output constant current setting, 0.000~5.000A, resolution 0.001A, unit A.
④ Output mode, including
- OFF mode,
- Constant Voltage output mode CV,
- Constant Current output mode CC,
in CV mode, the brightness of output LED automatically changes with the voltage,
and CC mode automatically changes with the current.
⑤ USB-A mode, including
- Host mode USBH
- Slave mode USBD.
In host mode, it can output 5V/1A , which can supply power to 5V devices, such as a USB mouse; in slave mode, it is
used for communication with the PC and firmware upgrading.。
⑥ Working state, including seven kinds:
- Normal state NM,
- OverVoltage Protection OVP,
- CverCurrent Protection OCP,
- OverPower Protection OPP,
- OverheaT Protection OTP,
- REverseconnection Protection REP(can be set through menu items),
- UnderVoltage Protection UVP.
When it detects other states than the normal state, the device automatically turns off the output
and alarms with a buzzer, and it is forbidden to turn on the output in the UVP state.
⑦ The preset output group currently used, the device supports 10 preset groups (0~9), P[0]
represents preset group 0, each preset group includes output voltage setting, output constant
current setting, overvoltage protection setting, overcurrent protection setting.
⑧ Panel lock state,
- gray means not locked,
- it turns orange after locking and operation is invalid,
it is automatically locked after connecting to the PC, and can’t be unlocked through panel.
⑨ Device temperature, unit: Celsius (°C).
⑩ Device output power, real-time display of the power value of the device, unit: watt (W).
⑪ Device output current, real-time display the output current value, unit: ampere (A).
⑫ Device output voltage, real-time display the output voltage value, unit: Volt (V)
- A mode that keeps the output voltage constant.
- Features:
- Maintains the set voltage while the current changes according to the load.
- Used when voltage stability is crucial (e.g., for digital circuits or testing electronic components).
- Operates as long as the output current does not exceed the set limit.
- Examples of Use:
- Powering microcontrollers and sensors.
- Voltage testing for LEDs or ICs.
- A mode that keeps the output current constant.
- Features:
- Maintains the set current while the voltage changes according to the load.
- Used when current regulation is important (e.g., for LED driving or battery charging).
- Operates as long as the output voltage does not exceed the set limit.
- Examples of Use:
- Battery charging.
- Controlling LED current.
- Motor testing.
- 出力電圧を一定に保つモード
- 特徴:
- 設定した電圧を維持し、負荷の変化に応じて電流が変化
- 主に電圧が重要な回路(デジタル回路や電子部品のテスト)に使用
- 電流が設定した制限値を超えない範囲で動作
- 使用例:
- マイコン、センサーへの電源供給
- LEDやICの駆動電圧テスト
- 出力電流を一定に保つモード
- 特徴:
- 設定した電流を維持し、負荷の変化に応じて電圧が変化
- 主に電流が重要な回路(LED駆動やバッテリー充電)に使用
- 電圧が設定した制限値を超えない範囲で動作
- 使用例:
- バッテリー充電
- LEDの電流制御
- モーターの試験
Ref. 定電圧と定電流を理解する